FHT 80B-2 PDF

Originally posted by: Hi, a quick question, I’ve noticed there appears to exist a FHTB II thermostat. The only thing I find on the. Jan. Hi, I’ve run into the issue with FHTB I’ve configured it in IP-Symcon and I’ve implemented the heating logic (for electrical heating using SU. FHT 80b & FHT 8V Combo Set Owner’s Manual Size: ( MB), All the information needed Works with additional FHT80TF-2 Window Contacts for automatic.

Author: Mejas Turisar
Country: Cambodia
Language: English (Spanish)
Genre: Environment
Published (Last): 27 March 2015
Pages: 283
PDF File Size: 7.61 Mb
ePub File Size: 18.94 Mb
ISBN: 445-3-15904-366-9
Downloads: 21254
Price: Free* [*Free Regsitration Required]
Uploader: Kigasida

Beyond that, you need a running FHEM device, in order to have a continuous log of your data in any way. It seems like Cht can go ahead with a conrad set. Actual temperature will be logged, etc But FHT80B’s main purpose is to control the room temperature using the radiator and is not usable as stand alone temperature sensor.

Which FHT thermostat kit to buy? I do not need to decouple this heating from a PC.

Any help for me? But I would also suggest the HMST F for this purpose though, unless you actually 80bb-2 to control your radiators with it, too. The FHT 80 on the other hand allows two way communication hence it being a little more expensive and absolutely the right choice if you want to do funky stuff with FHEM etc.

  LIVRO PRINCIPE DE MAQUIAVEL PDF

FHT 80B-2 not working with IP-Symcon

There’s no actual temperature reading coming from FHT for several hours. I can prove your problem: This is not optimal, as the FHT only accepts a command, when the final ack for the whole chain was sent.

However, nevertheless, basically a transference of the FHT functions fh the valve, or? Many thanks getting very excited from the goodies and toysDave. Results 1 to 10 of It appears they are compatible with FS20? Through the WS fhem 80n-2 receive the signals of the WS family. Will they also be usable for the “IST” or actual temperature?

To post to this group, send email to fhem-users googlegroups.

FHT 80b Wall Thermostat

I have my own heating algorithm in place, using FHT for temperature measurement and for setting a desired temperature. But with its un reliability, I will probably switch to thermometer and fth display in the room.

Bitte einloggen oder registrieren. The time now is The reason for my own control is that I control electrical device, not a valve.

The answer from Conrad: Forum Was ist neu? Therefore, one is well-advised if one gives the basic parametres in the FHT.

Anyway, yes, fhem can handle the FHT80b, however, since the fht80b is a wireless device and doesn’t have a serial port or anything like thatyou will also need either a CUL device from busware or an FHZPC or FHZPC where the later one can also receive data from some additional devices like the KS weather station.

  BA5415A IC PDF

I’m not sure if I am able to make this understandable. It is a Siemens fhht don’t remember exact type right nowand it appears to endorse X10 of some kind and possibly also simple serial communication via optional module. I try to use it to control electrical device, so the transfer of parameters is not enough.

80-b2 It is of course clear that systems only endorsed by communication through pc and FHEM won’t of course work when the pc is offline for some reason, but at that point, each separate system should be capable to continue to work individually: I consider an extension of the FHT. Will the cheaper FHT fth still work with the boiler interlock?

The FHT 8 is one way only – it will report its status, but is not capable of being controlled.