CS S10PKH PDF

Manuals and User Guides for Panasonic CS-S10PKH. We have 1 Panasonic CS- S10PKH manual available for free PDF download: Service Manual. View and Download Panasonic CS-S10PKH service manual online. CS-S10PKH Air Conditioner pdf manual download. Also for: Cs-s13pkh, Cs-s15pkh. Panasonic CS-S10PKH Manual Online: Cs-s18pk Cs-s24pk. Indoor Electronic Controllers, Cross Flow Fan and Indoor Fan Motor Removal Procedures.

Author: Mum Duran
Country: Cape Verde
Language: English (Spanish)
Genre: Spiritual
Published (Last): 12 September 2008
Pages: 241
PDF File Size: 14.80 Mb
ePub File Size: 5.31 Mb
ISBN: 391-2-84633-227-3
Downloads: 40835
Price: Free* [*Free Regsitration Required]
Uploader: Mizshura

The unit will operate fan operation, fan motor will operate at rpm for 30 minutes then stop.

The sunlight sensor sensitivity could be adjusted: This control can be omitted by open the circuit of JP1 at indoor unit printed circuit board. Fix the bushing to the sleeve. The internal setting temperature shift, fan speed and horizontal airflow direction are adjusted in order to provide comfort environment while maintain the energy saving level.

Do not use joint connection cable. Ensure that the capacitor has discharged sufficiently before proceeding with repair work. Attach the control board cover back to the original position with screw. If you are required to handle sharp parts during installation or servicing, please wear hand glove.

  BOWFLEX TC5000 MANUAL PDF

Then evacuate the air approximately ten minutes. Even if Air Swing button is pressed, no signal is sent to the unit and no change on remote control display. Be sure to connect the end of the charging hose with the push pin to the service port. Cut the sleeve until it extrudes about 15 mm from the wall. Remote Control Button Freeze Prevention Control 2 During installation, install the refrigerant piping properly before run the compressor.

Cs-s18pk Cs-s24pk – Panasonic CS-S10PKH Service Manual [Page ]

Otherwise, it will cause the set to fall, water leakage, fire or electrical shock. A place where drainage can be easily done. Do not install the unit near the door way. Enter text from picture: Remote control normal mode Press continously for 15s Transmit ECO demo code and after 2 seconds return to normal mode.

The reason for the compressor to force operation for minimum 30 seconds is to allow the refrigerant oil run in a full cycle and return back to the outdoor unit.

Cutting s10pih flaring the piping Please cut using pipe cutter and then remove the burrs.

  FOTOSINTESIS Y RESPIRACION CELULAR PDF

Panasonic CS-S10PKH Service Manual

To change remote control transmission code, short or open jumpers at the remote control printed circuit board. Lift to open the horizontal vane gently. If no activity detection, the last action will maintain for 30 seconds before changeover to human absence status. If connecting or fixing is not perfect, it will cause heat up or fire at the connection.

Using of existing R22 piping, fl are nut and tools may cause abnormally high pressure in the refrigerant cycle pipingand possibly result in explosion and injury.

A place where noise prevention is taken into consideration. Pull out the main At the same time, indoor fan speed will be higher than during its normal operation.